FIRES IN AGRICULTURAL CHEMICALS
by
Thomas L. Bean
West Virginia University
NRAES
With increased agricultural production, farmers are using more fertilizers
and chemicals. This has caused new problems for fire fighters due to the
numerous types of chemicals used and the increased chemical storage by farmers
and suppliers.
Fire fighters should spend more time with farmers and suppliers to pre-plan
in case of a fire. Trade name and formulations number in the thou- sands.
Not only are many of these chemicals poisonous for their intended use, but
many are toxic to humans both internally and externally. For this reason
proper storage, hazard identification, established emergency proced- ures,
and fire fighter training are extremely important.
Chemicals used by farmers and commercial applicators include: fertilizers,
soil conditioners, and pesticides.
Many of these chemicals release toxic fumes with little or no warning
when exposed to fire. Most serious are the organophosphate and chlorinated
hydrocarbons.
When fighting chemical fires wear protective clothing, use a self-contained
breathing apparatus (air paks), and have sufficient air available to complete
the job. For additional protection work on the upwind side of the fire.
FERTILIZERS
Although most fertilizers are quite stable, there have been problems
of fires and explosions with materials such as ammonium nitrate.
AMMONIUM NITRATE.
Like other inorganic nitrates, ammonium nitrate can be detonated if they
are in the proper crystalline form, if the initiating source is sufficiently
large, or if heated under sufficient confinement. The degree of confinement
necessary usually is greatest for the purest material.
Storage recommendations for bagged and bulk ammonium nitrate are published
in NFPA No. 490, Code for the Storage of Ammonium Nitrate. The Standard
covers building construction, pile sizes, spacing, and separation of ammonium
nitrate from contaminating material that could increase its sensi- tivity
during a fire. Also covered are flow, cleanliness of the storage area, and
precautions against ignition sources.
Fire fighting procedure for ammonium nitrate should include:
- Approach the fire from upwind side. Use a self-contained breathing
apparatus (vapors from decomposing ammonium nitrate are extremely toxic).
- Create as much ventilation as possible to permit smoke, gases and heat
to escape and to prevent pressure build-up.
- Flood the burning ammonium nitrate with water to reduce the temperature
of the burning material rapidly.
- Because ammonium nitrate is an oxidizing material (decomposes under
certain conditions to yield oxygen and increase a fire's intensity) smothering
agents such as inert gases, steam, foam, dry chemicals, sand, etc. will
have no effect.
ANHYDROUS AMMONIA.
Anhydrous ammonia can cause severe burns upon contact. Contact with the
liquid ammonia can also cause loss of sight, severe injury of the respiratory
membranes and varying degrees of irritation of skin, eyes and mucous membranes.
For these reasons, use adequate body protection -- self-contained breathing
apparatus with full face shields (air paks) and full protective clothing.
In addition to the air pak, if working around the shut- off valves, wear
rubber gloves and a rubber apron to protect the body from contact with liquid.
If exposed to liquid anhydrous ammonia, wash the exposed area with water
for at least 15 minutes or until the injured person receives medical attention.
Anhydrous ammonia fire fighting procedures should include:
- Stop the flow of the anhydrous ammonia gases by shutting off all valves
and disconnecting all hoses from storage, nurse, and applicator tanks.
- If in an enclosed area, ventilate the fire.
- Keep the storage vessels cool with the use of water.
- Anhydrous fires can be extinguished by the use of dry chemicals, carbon
dioxide, or a water spray.
- Always use proper personal protective equipment.
UREA.
Urea is classified as a non-flammable material by the Interstate Commerce
Commission. Urea will not support combustion by itself but melts at a temperature
of 534.2F. Above this point it begins to decompose, giving off mildly toxic
fumes. For this reason, the toxicity hazard of urea is given as slightly
dangerous.
Urea fire fighting procedure should include:
- Approach the fire on the upwind side.
- Flood the area to reduce the temperature of the burning mass.
- Provide adequate ventilation to prevent pressure, temperature and toxic
fumes build-up (self-contained breathing equipment is recommended to protect
personnel against toxic fumes).
PHOSPHATE FERTILIZER MATERIALS.
Phosphate fertilizers commonly used and stored in blending plants (triple
super phosphate, diammonium phosphate) will not support combustion and have
a melting point in excess of 1500 degrees Centigrade. Both of these are
rated as slightly dangerous in toxicity.
Fire fighting procedure should include:
- Flood the area to reduce the temperature.
- Provide adequate ventilation.
- Wear protective clothing and breathing apparatus.
POTASH FERTILIZER MATERIALS.
Muriate of potash is the principal potas- sium containing fertilizer
used as a bulk blending ingredient. It is rated slightly dangerous as a
fire and toxicity hazard.
Fire fighting procedure for muriate of potash is the same as for phosphate
fertilizer.
CHEMICAL FIRES
Fire in a warehouse or farm storage area where agricultural chemicals
are stored may create a great hazard to fire fighters, inhabitants, and
livestock because the possibility of poisoning is added to the usual fire
hazards. In addition, if proper fire fighting procedure is not followed,
water or chemicals used to fight the fire very easily could spread contamination
over a wide area. For this reason preplanning and training for chemical
fires are very important.
RECOMMENDATIONS
Pre-Fire Planning and Inspection for Local Fire Departments
- At least annually visit each large chemical storage warehouse and take
note of the following:
- General layout of the facility
- Locations of hydrants, normal and alternate access roads, gates, fences
- Surrounding building occupancies and land use
- Means of ventilation
- Means of controlling drainage at and adjacent to the facility.
- Prepare a list of day and night telephone numbers of:
- Facility operators
- Physician (familiar with the products)
- Poison Control Center
- Manufacturers of the products
- Establish a card file on each facility to make the officer aware of
the hazards he might face in fighting the fire.
- Establish a reference manual of the systems of poisoning and what to
do in case of contact with the chemicals stored in the facility.
- Recommend chemical storage procedures to owners or managers. Chemicals
should be stored away from other fire hazards.
POST-FIRE CLEAN-UP
Personal Precautions.
- Remove protective clothing upon leaving site and impound with contaminated
fire fighting equipment.
- Upon returning to the station, shower and shampoo thoroughly with soap
and water to remove traces of toxic chemicals.
- Wash inner clothing with detergent and put on clean clothes.
- Watch for signs and symptoms of pesticide poisoning.
- Wash all personal clothing, protective clothing and respirators in
an isolated area. Put on coveralls and rubber gloves and use respiratory
protection when cleaning clothing and equipment.
Fire Site.
- Isolate and secure scene to keep people away.
- Contact public health department for disposal instructions and approval.
- Handle waste and run-off same as for a product spill -- personal protective
equipment is required.
- Be aware of aid available to you. The National Agricultural Chemicals
Association has a network of safety teams to assist you in case of major
pesticide spillage such as may result from a fire. To contact NCA, telephone
Cincinnati, Ohio (513) 961-4300 and ask for help.
- The Chemical Transportation Emergency Center (CHEMTREC) provides emergency
personnel with information on safety measures in handling hazardous chemicals
involved in accidents on the nation's highways, railroads, and waterways.
Assistance is available 24 hours a day, seven days a week. Their nationwide
emergency telephone number is (800) 424-9300.
FIGHTING FIRES INVOLVING AGRICULTURAL CHEMICALS
- After receiving call of a fire involving chemicals, notify physician
and hospitals to be prepared to receive possible poison victims. (Hospitals
should have a card file on each storage facility listing the type of chemicals
stored and the manufacturer of each.)
- Evacuate the downwind area and isolate the area. Patrol this area to
keep spectators out.
- Before attempting to fight the fire use the correct personnel protective
equipment. This includes the use of rubber gloves, boots, turn-outs, and
helmets. If contact cannot be avoided also wear self-contained breathing
apparatus.
- Avoid working in areas on the downwind side of the fire. Attack the
fire from a safe distance. Bottles, drums, metal and aerosol cans are not
vented and may explode.
- Attempt to contain the fire and protect the surroundings. Prevent the
spread of the fire by cooling nearby containers to prevent rupture.
- Avoid raising a flammable, explosive, or toxic dust.
- Use soft streams such as fog so as not to tear open paper containers
or break jars.
- Use foam when large volumes of flammable solvents are released from
ruptured metal or glass containers.
- Cool drums containing flammable solvents with water spray.
- Keep a safe distance in case of explosion.
- Avoid using large quantities of water to keep toxic run-off to a minimum.
Construct dikes to prevent flow into lakes, streams, sewers, etc. (Cooling
effect of water retards high-temperature decomposition of chemicals to
less toxic compounds).
* * * *
Disclaimer: Please read
the pesticide label prior to use. The information contained at this web
site is not a substitute for a pesticide label. Trade names used herein
are for convenience only; no endorsement of products is intended, nor is
criticism of unnamed products implied. Most of this information is historical
in nature and may no longer be applicable.
To Top
For more information relative to pesticides and their use, please contact the PMEP staff at:
Pesticide Safety Education Pgm.
5123 Comstock Hall
Cornell University
Ithaca, NY 14853-0901
(607) 255-1866 |
Pesticide Sales & Use Reporting Database Grp.
Cornell University
20 Thornwood Dr. #106
Ithaca, NY 14850
(607) 257-5706 |
|
 |
This site is supported, in part, by funding from the
 |
Questions regarding the development of this web site should be directed to the
PMEP Webmaster